PLC with Touch Screen
Touch operation with self-diagnosing fault alarms.
- Mitsubishi PLC (Japan)
- Weilun or Inovance touch screen





Continuous extrusion blow molding machine with a standard clamping system, for 5 ml–2 L PE and PP bottles such as cosmetic and beverage containers. Single and double station models.

Touch operation with self-diagnosing fault alarms.

Reliable electrical components ensure stable machine operation, precise temperature regulation and consistent process control.

Inverter drive on a Siemens motor and hard-gear gearbox.


Double proportional control for precise, stable movements.

Quiet, efficient oil supply for the hydraulic system.

Heating Mode: Using ceramic heating ring, temperature control accuracy ±2%, uniform force makes the cut be flat.

Efficient fan cooling helps maintain stable operating temperatures during continuous machine operation.
| Item | Unit | GRT50-2LI | GRT60-2LII |
|---|---|---|---|
| Specifications | Single station | Double station | |
| Material | PE, PP… | PE, PP… | |
| Max. container capacity | L | 2 | 2 |
| Output (dry cycle) | pcs/h | 1,500 | 900 × 2 |
| Machine dimensions (L × W × H) | m | 3.1 × 1.7 × 2.4 | 3.3 × 2.2 × 2.4 |
| Total weight | t | 3.2 | 4.3 |
| Clamping unit | |||
| Clamping force | KN | 40 | 40 |
| Platen distance | mm | 130–370 | 130–370 |
| Mold moving stroke | mm | 370 | 370 |
| Platen size (W × H) | mm | 300 × 335 | 300 × 335 |
| Max. mold size (W × H) | mm | 300 × 335 | 300 × 335 |
| Extruder unit | |||
| Screw diameter | mm | 50 | 60 |
| Screw L/D | 22 | 25 | |
| Screw motor power | KW | 11 | 15 |
| Extruder heating power | KW | 4.2 | 6.5 |
| Heating zones | 3 | 3 | |
| Melting capacity | kg/h | 35 | 70 |
| Die head | |||
| Heating zones | 3 | 3 | |
| Die heating power | KW | 5.2 | 5.2 |
| Max. die-pin diameter | mm | 100 | 100 |
| Center distance, double die | mm | 120–130 | 120–130 |
| Center distance, triple die | mm | 85 | 85 |
| Center distance, four die | mm | 60–65 | 60–65 |
| Power | |||
| Total power | KW | 22 | 26 |
| Hydraulic pump motor | KW | 5.5 | 5.5 |
| Air pressure | MPa | 0.6 | 0.6 |
| Air consumption | m³/min | 0.4 | 0.5 |
| Cooling water pressure | MPa | 0.3 | 0.3 |
| Water consumption | L/min | 35 | 50 |
| Average energy consumption | KW | 12 | 15 |
Earlier models and products. For the current design and specifications, see above.








Send us your container volume, material and output. We'll match the stations, die heads and mold, then recommend a model.
We use your details only to answer your inquiry. See our privacy policy.